Enclosure Ratings

NEMA Classifications and Ingress Protection (IP) Codes

   Class    (IP code) Title

Description

1 (10) General Purpose Unventilated/Ventilated for indoor use limited amounts of falling dirt
2 (11) Drip Tight Unventilated/Ventilated for indoor use with limited amounts of falling dirt and water.
3 (54) Weather Resistant Unventilated for outdoor use with rain, sleet, windblown dust, and external ice damage.
3R - Unventilated/Ventilated for outdoor use with all of the above except windblown dust.
3S - Unventilated for outdoor use with all of the above and will ensure external mechanisms will function when ice laden.
4 (56) Water Tight (Weatherproof) Unventilated for indoor/outdoor use with windblown dust and rain, splashing and hose-directed water, and external ice damage.
4X - Unventilated for indoor/outdoor use with all of the above including corrosion.
5 (52) Dust Tight Unventilated for indoor use with settling dust, falling dirt, and dripping non-corrosive liquids.
6 (67) Submersible Unventilated for indoor/outdoor use with hose-directed water, entry of water from submersion.
7 Hazardous Unventilated for indoor use in NEC defined Class I, Groups A, B, C, or D.
8 Hazardous Unventilated for indoor/outdoor use in NEC defined Class I, Groups A, B, C, or D.
9 Hazardous Unventilated for indoor use in NEC defined Class II, Groups E, F, or G.
10 Mines Unventilated to meet the applicable requirements of the Mine Safety and Health Administration.
12 (52) Industrial Use Unventilated for indoor use with circulating dust, falling dirt, and dripping non-corrosive liquids.
12K - Unventilated for indoor use with knockouts for above conditions.
13 (54) Oil Tight Unventilated for indoor use with dust, spraying water, oil, and non-corrosive coolant.

Code First Number
(Protection against solid bodies)
Second Number
(Protection against liquid)
0 No protection No protection
1 Objects greater than 50mm Vertically dripping water
2 Objects greater than 12mm 75° to 90° dripping water
3 Objects greater than 2.5mm Sprayed water
4 Objects greater than 1mm Splashed water
5 Dust protected Water jets
6 Dust tight Heavy seas
7   Effects of immersion
8   Indefinite immersion